General Purpose InverterV1000 Series
Industry Leading High Performance Inverter
Industry Leading High Performance Inverter
CLV high-performance general-purpose inverters are developed on the platform of high-performance vector technology, adopting open-loop vector control algorithm, and supporting both asynchronous motor and permanent magnet (PM) motor control. CLV drives can improve the output performance by 20% and achieve lower power consumption, with reasonable arrangement and layout of all components. CLV drives also support different expansion interface, and new generation of expansion options, to meet the requirement of high performance, high reliability, high flexibility, high power density, and high applicability.
Our products are designed and ideal for equipment manufacturing, environmental protection, and new energy systems, and widely used by industries like lifting, machine tools, metal products, wire and cable, plastic cement, printing and packaging, textile and chemical fiber, building materials, metallurgy, petroleum, municipal affairs, automobile, etc.
Dimension
- No. W(mm) D(mm) H(mm)
- A0086131.5170
- A0196151180
- A02113166.5221.6
- A03160171.5265
- A04192171.5302.5
- A05227171.5348.5
- A06327.5238490
- A07300304526
- A08370350690
- A09410360720
- A10600380963
- A11818404.51361.5
Installation Size
- No. W(mm) H(mm) Hole Φ (mm)
- A00751595
- A0183.6165.25
- A0298.72025
- A03143244.36.5
- A041722778.5
- A05208.53238.5
- A06202.545910
- A072005049
- A08302635.510
- A0933069010
- A1040093312
- A11520128016
Products Series
220V Single Phase Input
- Inverter model kW HP Rated output current(A) Frame
-
V1000-V0004G1 0.4 0.5 2.5 A00
-
V1000-V0007G1 0.75 1 4 A00
-
V1000-V0015G1 1.5 2 7 A00
-
V1000-V0022G1 2.2 3 10 A01
380V three phase input
- Inverter model kW HP Rated output current(A) Frame
-
V1000-V0007G3 0.75 1 2.5 A00
-
V1000-V0015G3 1.5 2 3.7 A00
-
V1000-V0022G3 2.2 3 5.1 A01
-
V1000-V0040G3 4 5 8.5 A01
-
V1000-V0055G3 5.5 7.5 13 A02
-
V1000-V0075G3 7.5 10 16 A02
-
V1000-V0110G3 11 15 25 A03
-
V1000-V0150G3 15 20 32 A03
-
V1000-V0185G3 18.5 25 38 A04
-
V1000-V0220G3 22 30 45 A04
-
V1000-V0300G3 30 40 60 A05
-
V1000-V0370G3 37 50 75 A05
-
V1000-V0450G3 45 60 90 A06
-
V1000-V0550G3 55 70 110 A06
-
V1000-V0750G3 75 100 150 A07
-
V1000-V0930G3 93 125 170 A07
-
V1000-V1100G3 110 150 210 A08
-
V1000-V1320G3 132 175 250 A08
-
V1000-V1600G3 160 210 300 A09
-
V1000-V1850G3 185 245 340 A09
-
V1000-V2000G3 200 260 380 A09
-
V1000-V2200G3 220 300 415 A09
-
V1000-V2500G3 250 350 470 A10
-
V1000-V2800G3 280 370 520 A10
-
V1000-V3150G3 315 400 600 A10
-
V1000-V3550G3 355 420 650 A11
-
V1000-V4000G3 400 530 725 A11
-
V1000-V4500G3 450 595 820 A11
-
V1000-V5000G3 500 660 980 A11
Technical Specification
- Item Specifications
-
Control System
High performance of current vector control technology to realize 3 phase
asynchronous motor control - Drive Performance High efficiency driving for induction motor and synchronous motor
- Maximum Frequency Vector Control: 0~500Hz V/F Control: 0~500Hz
- Carrier Frequency 0.5kHz~16kHz; the carrier frequency will be automatically adjusted according to the load characteristics
- Input Frequency Resolution Digital Setting:0.01Hz
-
Control Mode
Open Loop Vector Control(SVC)
V/F Control - Startup Torque G Type: 0.5Hz/150%(SVC);0Hz/180%(FVC) P Type: 0.5Hz/100%
- Speed Range 1:100(SVC)
- Speed Tracking Prevent overload, overcurrent, and overvoltage caused by motor stall
- Speed Stabilizing Precision ±0.5%(SVC)
-
Over Load Capability
G Type: 150% rated current 60 seconds; 180% rated current 3 seconds;
P Type: 120% rated current 60 seconds; 150% rated current 3 seconds - Torque Boost Auto Torque Boost Function;Manual torque boost 0.1%~30.0%
- V/F Curve Linear V/F, multi-point V/F and square V/F curve (power of 1.2, 1.4, 1.6, 1.8, 2)
- V/F Separation In 2 ways: separation, semi separation
-
Acc. / dec Curve
Straight line or S curve acceleration and deceleration mode.
Four kinds of acceleration and deceleration time. Acceleration and deceleration time range between 0.0s to 6500s. -
DC Brake
DC Brake Frequency: 0.00Hz to maximum frequency. Brake time: 0.0s to 36.0s
Brake current value: 0.0% to 100.0%. -
Jog Control
Jog Frequency Range: 0.00Hz~50.00Hz.
Jog Acceleration/deceleration Time 0.0s~6500.0s. - Simple PLC and Multi-speed Running It can realize at maximum of 16 segments speed running via the built-in PLC or control terminal.
- Built-in PID It is easy to realize process-controlled closed loop control system
- Auto Voltage Regulation (AVR) It can keep constant output voltage automatically in the case of change of network voltage.
- Over-voltage/current Stall Control It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running process
- Quick Current Limit Minimize the over-current fault, protect normal operation of the Inverter
-
Torque Limit & Control
"Excavators" characteristics, automatically limit torque during operation, prevent frequent
over-current tripping.
Closed loop vector mode can realize the torque control.
Personalized
- Item Specifications
- Mains loss Ride Through When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make Inverter keep running in a short period of time.
- Rapid Current Limit To avoid Inverter frequently over-current fault.
- Timing Control Timing control function:set time range 0Min~6500.0Min
- Running Command Channel Three types of channels: operation panel reference, control terminal reference and serial communication port reference. These channels can be switched in various modes.
- Command Source Operation panei reference, control terminal reference, and serial COM port reference. It can be switched in various ways.
- Frequency Source There are totally eleven types of frequency sources, such as digital reference, analog voltage reference , analog current reference, pulse reference, and serial port reference. It can be switched in various ways.
-
Input Terminal
Standard:
5 Digital input terminals
2 Analog input terminals
1 Support 0-10V voltage input or 0~20mA current input. -
Output Terminal
Standard:
2 Digital output terminals
1 Relay output terminal, which can be expanded into 2 channels
1 Analog output terminals, support 0~10V output voltage; - Keypad Potentiometer Equipped with Keypad potentiometer or coding potentiometer.